The data in TABLE 1 below relates to a specific heat exchanger. A reliable colleague has looked up an effectiveness chart and says that the effectiveness in the given operating conditions is 0.55. Data: ‘Hot’ fluid ‘Cold’ fluid Mass flowrate kg s-1 0.7 0.4 Specific heat capacity kJ kg-1 K-1 1.44 4.2 Inlet temperature ֩C 130 18 Overall heat transfer coefficient 112 W m-2 K-1 Area of heat transfer surface 9 m2 Determine: (i) The outlet temperature of the hot fluid. (ii) The outlet temperature of the cold fluid. (iii) The heat transfer rate. Calculate the correction factor. Dry saturated steam at a temperature of 180ºC is to be produced in a fire tube boiler from the cooling of 40 000 kg h-1 of flue gases from a pressurised combustion process. The gases enter the tubes of the boiler at 1200ºC and leave at 250ºC. The feed water is externally preheated to 180ºC before entering the boiler. (Assume the exchanger is counter-flow) The mean specific heat capacity of the flue gases is 1.15 kJ kg-1 K-1. Feed water temperature = 180ºC. (a) Find the log mean temperature difference (b) Calculate the heat transfer rate (c) Determine the area of heat transfer required to perform this duty if the overall heat transfer coefficient based on the outside area of the tubes is given as 45 W m-2 K-1. The tubes within the boiler are to be 38 mm inside diameter with a wall thickness of 4 mm. The average flue gas velocity through the tubes to maintain the overall heat transfer coefficient value and to minimise pressure losses is to be more than 20 m s-1 and less than 26 m s-1. The average density of the flue gases is 1.108 kg m-3. Calculate the minimum and maximum number of tubes in each pass Calculate the overall length of tubes at each of these numbers of tubes Find the minimum number of tube passes in each case, if the length of a boiler tube is to be less than 4 metres.
ES
EssayPanel Expert
Academic Expert · EssayPanel
Expert academic writer and education specialist helping students in the UK, USA, and Australia achieve their best results across all subjects.
Need help with your own assignment?
Our expert writers can help you apply everything you've just read — to your actual assignment, brief, and marking criteria.
Get Expert Help Now →← Previous
IMA7001 Strategic Case Study Report: Global Marketing in Crisis Scenario: Brief Background on the E-Commerce Sector The IMA7001 International Marketing Management Assessment Brief 2026 requires
Next →
A small reheating furnace wall consists of 200 mm of firebrick. The inner surface of the wall is at a temperature of 320 ℃ and the outside temperature is 25 ℃ Calculate the rate at which the heat is transferred, by conduction